OXIDIZING SOLIDS TEST
test O.1 & test O.3
model: BB-12 & BB-13

OXIDIZING SOLIDS TEST APPARATUS
TEST FOR OXIDIZING SOLIDS
STANDARD REFERENCES: 
UN Recommendation on the Transport of Dangerous Goods. Manual of Tests and Criteria, 
Test O.1: Test for oxidizing solids.
Test O.3: Gravimetric test for oxidizing solids.

SPECIFICATION:
Gloving wire length:                    30 cm
Gloving wire diameter:                 ø0,6 mm
Wire heating power:                   150W 
Insulating plate :                        150x150 mm
Glass plate:                               quartz glass
Plate holder:                              stainless steel
Glass funnel:                              60°, 70mm
Power supply:                            110 / 230 VAC
Remote switch:                          on/off
Wire forming rig:                         as per O.1 test