MAIT - MINIMUM AUTOIGNITION TEMPERATURE
OF A DUST CLOUD
STANDARD REFERENCES:
• VDI 2263 part 1, point 2.6.1.1 Ignition Temperature. BAM oven
• ASTM E1491-06 Standard test method for minimum autoignition temperature of dust clouds.
• EN ISO/IEC 80079-20-2 Explosive atmospheres. Material characteristics. Combustible dust methods
SPECIFICATION:
• Heating tube high-tech temperature block
long-life ceramics
• Body stainless steel
• Thermocouples 2x type K
Inconel shield
silicone cables
• Dispersion nozzles acc. to standard dimensions
ANKO design nozzle
• Temperature up to 600°C
• Power supply 110 or 230VAC, 1200 VAC